ULTIMIX
Installation & Maintenance:
UltiMix Series
"ULTIMIX" dispenses BOILING water – Please treat with care.
Do not use the "ULTIMIX" for washing hands
Supply temperature – 5 deg to 35 deg
This unit is fitted with a computerised element and boil dry protection.
Altitude will alter temperature (refer back to manufacturer)
* Rapid action ¼ turn tap handles
* No drainage or overflow is required
* The tap vents through the tap spout
Components supplied with the unit;
-
Chiller unit
-
Boiling water unit
-
Tap dispenser
-
Aquaknect flexible connector – 450mm long (Do not over tighten)
-
Combined dual check valve with 350 Kpa PLV (Connected to boiling water unit)
* If fitted with filter we recommend changing the cartridge every 6 months
* The manufacturer recommends the cleaning and service of the unit every 12 months
* IF SUPPLIED CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED SERVICE AGENT (ELECTRICIAN).
Installation instructions – model ULTIMIX series
Do not plug in or turn on power - Unit must be positively earthed
- Position the tap head on a flat area in an appropriate location (i.e. Tea room sink), Drill 38mm diameter hole, washer supplied.
- Position boiling water unit underneath the sink directly beneath the tap head.
- Observe attached labels (ensure when pipes are cut – deburr ends before fitting).
- Connect 5/16” outlet from the tap head spout to the boiling water unit, NB: The pipe must not be extended and must have continuous fall between tap and boiling water unit.
- Connect inlet pipe from the tap body to the boiling water unit (inlet).
- Connect main water supply from the tap body to the outlet side of the filter head.
- Connect the 3/16” nylon tube from the tap to the 3/16” copper vent pipe on the boiling water unit. (heat nylon tube ends in boiling water to ensure easier fitting).
- Position the chiller unit adjacent to the boiling water unit with a minimum clearance between the units of no less than 50mm.
- Connect inlet and outlet pipes from the tap head to chiller unit as per markings.
- Connect aquaknect flexible hose to PLV (inlet side of the filter head).
- Open both taps until the water is flowing from both spouts. 18 litres of water must be flushed through filter before turning on power.
- Plug units into the power point and switch on.
TYPICAL INSTALLATION |
TROUBLE SHOOTING
Action to be performed by a qualified person.
BOILING WATER UNIT
SYMPTOM | CAUSES | ACTION |
No Water | Water supply turned off | Check mains supply |
Blocked Filter | Replace Cartridges | |
Water not hot | Faulty element and computer | Replace dual computerised element |
No power supply | Check and test power supply | |
Water overflowing from tap spout | Expansion chamber full | Run tap for 5 – 10 mins, this will correct water level in expansion tank |
Low inlet pressure | Contact manufacturer | |
Boiling On | Replace element | |
Excessive steam from tap | Fault element | Replace element |
The boiling water unit is designed to have no less than 150ml off at any one time. |
TROUBLE SHOOTING
Action to be performed by a qualified person.
CHILLED UNIT
SYMPTOM | CAUSES | ACTION |
No water | Water supply turned off | Check mains supply |
Blocked Filter | Replace cartridges | |
Water not cold | Thermostat | Not set correctly |
Loss of gas | Contact manufacturer | |
Failed fan | Contact manufacturer | |
No power supply | Check and test power supply | |
Poor ventilation | Clean cabinet louvers (if fitted) & condenser fins - these units need ventilation | |
Faulty element |
Replace element |
Australian Service Agents
New South Wales
Boiling Billy
Click to view full detailsContact: Tania Wiffen
Phone: +61 (0) 3 5248 7072
Fax: +61 (0) 3 5248 7272
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
1/33 Cedar Parade, Moolap, VIC, 3224
Northern Teritory
Boiling Billy
Contact: Tania Wiffen
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
1/33 Cedar Parade, Moolap, VIC, 3224
Queensland
Mark Anderson Sales
Building 4, 84 Ingleston Rd, Wakerley, QLD, 4154
South Australia
Boiling Billy
Click to view full detailsContact: Tania Wiffen
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
1/33 Cedar Parade, Moolap, VIC, 3224
Tasmania
Boiling Billy
Contact: Tania Wiffen
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
1/33 Cedar Parade, Moolap, VIC, 3224
Victoria
Interchange Sales And Marketing
Contact: Kevin Cottom
Unit 4, 49 Corporate Blvd, Bayswater, VIC, 3153
Western Australia
Pride Industries
23 Munt Street
Bayswater WA 6053
Ph: 08 9272-6511 Fax: 08 9272-3427
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
Complete Enviro Solutions
Contact: Ken