Mini Boil 'n Chill
Mini Boil 'n Chill Installation & Maintenance
Installation & Maintenance:
MBC series above sink Boiling Billy mini boil n' chill
This unit dispenses boiling water – please treat with care.
If a tundish is to be used, it must be placed in accordance with your plumbing authorities regulations.
If fitted with filter we recommend changing the cartridge every 6 months.
The manufacturer recommends the cleaning and service of the unit every 12 months.
Installation instructions – model MBC series
Do not plug in or turn on power
- Remove four screws from plastic case and remove cover.
- Mount unit on the wall using fixing points on the back of the unit. Unit is to be positioned 300-350mm above a drain board when possible, so that in the event of filling cups, etc. Spillage occurs, water is disposed via sink.
- Connect cold water supply to inlet (12mm) through a stop tap in the supply line. (stop tap to be supplied by the installer). Provision is made for concealed plumbing or out of the bottom of the unit.
- Connect overflow pipe to waste (12mm). Check with plumbing regulations in your state. Do not block the overflow pipe.
- Place plastic cover back onto the unit and secure with the four screws.
- Fit red handle tap onto the left hand side inlet (boiling water) and the black handle tap onto right side inlet (chilled water).
- Plug unit into 10amp power inlet (do not turn on the power).
- Turn 'on' water supply to the unit and 'open' the red handle tap only until water flows out of the tap. If fitted with internal filter flush 18 litres of water through unit.
- When the water flows out of the red handle tap and the chiller tap, please switch the power on.
Allow approx. 30 minutes before use
Only teflon tape to be used where necessary, under no circumstances is plumbers paste to be used.
Do not connect to hot water line – to do so will void warranty.
TROUBLE SHOOTING
Action to be performed by a qualified person.
CHILLED UNIT
SYMPTOM | CAUSES | ACTION |
Water overflowing | Water level too high | Check and set approx 20mm. Below the overflow pipe inside the flow tank. Remove ball valve body and Insert, clean and reinstall and Adjust ball valve arm if necessary. Remove ball valve float and Check to ensure that there is no water in it. Replace if necessary. Ensure ball valve closes (does not leak). |
Not cold | Power not on | Check if power is turned on. |
Faulty thermostat | Contact service agent or Manufacturer. | |
Faulty compressor | Contact service agent or Manufacturer. | |
Loss of Gas | Contact Manufacturer. | |
Poor ventilation | Clean cabinet louvers (if fitted) and condenser fins (located under fan). The unit must have ventilation. | |
No water | Water has been turned off | Turn on water. |
Blocked ball valve | Remove ball valve and clean or replace if necessary. | |
Blocked filter | Replace if necessary. | |
Faulty thermostat | Check to ensure that thermostat has not been turned to cold all the way, this will freeze the unit. | |
RATING CONDITIONS PERFORMANCE |
TROUBLE SHOOTING
Action to be performed by a qualified person.
BOILING WATER UNIT
SYMPTOM | CAUSES | ACTION |
Water overflowing | Water level too high | Check and set approx 20mm.Below the overflow pipe inside the flow tank. (Bend arm if necessary) Remove ball valve body and Insert, clean and reinstall. Adjust ball valve arm if necessary. Remove ball valve float and check to ensure that there is no water in it. Replace if necessary. |
Continuous Boiling | Ball valve defective | Ensure ball valve closes off. |
Faulty element | Replace element. | |
Water is not hot | Power not on | Check if power is on. |
Element Faulty | Replace element. | |
Water has been turned off | Turn on water. | |
Blocked ball valve | Remove ball valve and clean out or replace if necessary. | |
No water | Blocked flow tank (hole) | Remove arm and ball float from the flow tank and using 3mm diam wire clean out the hole situated near the bottom of the flow tank. |
Blocked filter | Change filter cartridge. |