Above Sink Boiling Billy
JE & JR Series Installation & JE, JR & SBB Maintenance
Installation & Maintenance:
Boiling Billy JE & JR Series.
The above sink BOILING BILLY dispenses BOILING water - PLEASE treat with care.
If a tundish is to be used, it must be placed above the sink in the open.
Important: Maximum inlet pressure 820kpa. JE & JR units must be fitted with an approved 350kpa pressure limiting valve.
Minimum inlet pressure 200kpa. If a lower pressure is encountered refer to manufacturer.
Important: POWER MUST BE OFF UNTIL INSTALLATION IS COMPLETED.
This unit is fitted with a computerised element and boil dry protection.
The computer is set at 97ºC, altitude will alter temperature.
- If fitted with filter we recommend changing the cartridge every 6 months.
- The manufacturer recommends cleaning and service of the unit every 12 months.
- IF SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED SERVICE AGENT (ELECTRICIAN).
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
DO NOT MEGGER
INSTALLATION INSTRUCTIONS
Action to be performed by a qualified person.
Model JE & JR Series Above Sink
Do not plug in or turn on power
Only Teflon tape to be used where necessary.
Under no circumstances is plumbing paste to be used.
Do not connect to hot water line - to do so will void warranty.
- Fit tap and shank onto the outlet connection provided.
- Mount unit on the w all using fixing points on the back of t he unit. It is advisable t o position the tap outlet over a drain board so that in the event of a leaking tap the water can be disposed via the sink.
- Connect cold water supply to the inlet (12mm)through a stop tap in t he supply line . (Stop tap to be provided b y t he installer).
- Connect overflow pipe to waste or any other area where water can be disposed in a safe manner .
- Plug unit into 10 amp power outlet.
- Turn ‘on ’ water supply to the unit and ‘open ’ the outlet tap .
- Wait until the water flows out o f the tap .
- When the water flows out of the tap please s w itch on the power .
*3.6kw element requires a 15amp power outlet. Unit must be positively earthed.
TROUBLE SHOOTING
Action to be performed by a qualified person.
JE, JR & SBB Series
SYMPTOM | CAUSES | ACTION |
Water Overflowing | Water level too high. | Check and set water level to indicated level 20mm below overflow pipe. |
Remove ball valve insert. Clean and reinstall and adjust ball valve arm if necessary. | ||
Remove ball valve float and check to ensure that there is not water in it. | ||
Replace if necessary. | ||
Continuous boiling. | Ball valve defective. | Ensure ball valve close off (does not leak).Replace if necessary |
Faulty element | Replace element. | |
Water not hot. | Power not on. | Check if power is on. |
Element faulty. | Replace element. | |
No water. | Water has been turned off. | Turn on water. |
Blocked ball valve. | Remove ball valve and clean out hole, or replace ball valve. | |
(Units fitted with flow tank) Blocked flow tank. |
Clean out hole with 3mm wire that is situated at the bottom of the flow tank. | |
Blocked filter. | Change filter cartridge. | |
Units fitted with mini ball - located inside case, at base inlet side. |
Fully open mini ball valve and re-adjust water flow as per instructions on the side of the case. |