Print

Under Sink Boiling Billy

Undersink TD Series Installation & Maintenance

Installation & Maintenance:

Boiling Billy Undersink TD series.

IMPORTANT - Please read

This undersink BOILING BILLY dispenses BOILING water – Please treat with care.
Do not use the undersink BOILING BILLY for washing hands.

Important: this unit must be installed by an authorised plumber.
Warning: unit is to be connected in accordance with as3500.4.1 or as/nzs 3500.4.2

Important: Do not regulate water flow with the tap. Have your plumber install a pressure limiting vale if pressure exceeds manufacturers recommendations (350Kpa).

For areas with pressure above 350 Kpa, an authorised 350 Kpa only pressure limiting valve must be fitted for maximum efficiency.

*Maximum inlet pressure 350 Kpa
*Minimum inlet pressure 250 Kpa

This unit is fitted with a computerised element and boil dry protection. The computer is set at 97°, altitude will alter temperature (refer to manufacturer).

Warning:A backflow prevention device complying with the requirement of A.S. 3500 I is required to be installed on the water supply inlet to this unit.

DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE TAP.

  • If fitted with filter we recommend changing the cartridge every 6 months

  • The manufacture recommends the cleaning and service of the unit every 12 months

  • IF SUPPLIED CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED SERVICE AGENT (ELECTRICIAN).

Please leave these instructions with the owner.

 

 

INSTALLATION INSTRUCTIONS
Action to be performed by a qualified person.
Model TD Series Undersink
Do not plug in or turn on power

1. Position heater unit underneath the sink as close as possible to its outlet tap.

td1

3. OBSERVING THE ATTACHED LABELS

  1. Measure and cut pipes to desired length.
  2. Connect the ¼” pipe from the tap to the inlet of the heater.
  3. Connect the 5/16” pipe from the tap to the outlet of the heater.
  4. Connect the ¼” pipe from the tap to the water supply via an approved back flow device.
  5. Connect the flexible tubing from the tap to the vent pipe of the heater. (Place the end of the flexible tube in hot water and then push onto the copper.

td3

td2


2. Position the tap in the desired location. Drill 35mm hole.

td4

4. All pipes and tubes must not be extended and must have a continuous fall between tap and heater.

5. OPEN TAP UNTIL WATER IS FLOWING FROM THE SPOUT.

6. Plug unit into power point and switch on.

 

Warning: UNIT MUST BE POSITIVELY EARTHED

Before using we recommend the fitting of a water filter.
Only Teflon tape to be used where necessary.
Under no circumstances is plumber’s paste to be used.

td5

TYPICAL INSTALLATION
N.B. When fitting this unit in a cupboard of small proportions, please note that the unit does omit heat.
If in doubt fit cross flow vents.

DO NOT connect to hot water line – to do so will void warranty.
AFTER POWER IS ON – allow 30 minutes before using.

 

 

TROUBLE SHOOTING
Action to be performed by a qualified person.
Undersink TD Series

SYMPTOM CAUSES ACTION
No Water

 

Water supply turned off Check mains supply
Blocked filter  
Water not hot

 

Faulty element Replace element
No power supply Check and test power supply
Water overflowing from tap spout

 

Expansion Chamber full Run tap for 5-10 minutes
Low inlet pressure Contact Manufacturer
Excessive steam from tap Faulty element Replace element
NB: These units are designed to have no less than 100ml of boiling water taken off at a time.

Australian Service Agents

New South Wales

Boiling Billy

Click to view full details

Contact: Tania Wiffen

Phone: +61 (0) 3 5248 7072
Fax: +61 (0) 3 5248 7272

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

1/33 Cedar Parade, Moolap, VIC, 3224

Northern Teritory

Boiling Billy

Click to view full details

Contact: Tania Wiffen

Phone: +61 (0) 3 5248 7072
Fax: +61 (0) 3 5248 7272

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

1/33 Cedar Parade, Moolap, VIC, 3224

 

Queensland

Mark Anderson Sales

Click to view full details

Phone: (07) 3890 8011
Fax: (07) 3890 8022

Building 4, 84 Ingleston Rd, Wakerley, QLD, 4154

 

South Australia

Boiling Billy

Click to view full details

Contact: Tania Wiffen

Phone: +61 (0) 3 5248 7072
Fax: +61 (0) 3 5248 7272

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

1/33 Cedar Parade, Moolap, VIC, 3224

 

Tasmania

Boiling Billy

Click to view full details

Contact: Tania Wiffen

Phone: +61 (0) 3 5248 7072
Fax: +61 (0) 3 5248 7272

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

1/33 Cedar Parade, Moolap, VIC, 3224

 

Victoria

Interchange Sales And Marketing

Click to view full details

Contact: Kevin Cottom

Phone: (03) 9729 6411
Fax: (03) 9729 5722
Mobile: 0415 934 913

Unit 4, 49 Corporate Blvd, Bayswater, VIC, 3153

 

Western Australia

Pride Industries

23 Munt Street
Bayswater WA 6053

Ph: 08 9272-6511  Fax: 08 9272-3427

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Complete Enviro Solutions

Contact: Ken

Mobile: 0429 028 285

Contact: Ryan

Mobile: 0408 363 645

Click to view full details